Typhoon with the Ep-Sh-N Ionising Bar

The airknife is constructed of extruded aluminium with incorporated mounting grooves. This design provides a precise air volume over the entire width of the airknife. In the airkife tube a high air pressure appears and is flowing out of the airknife narrow outflow opening. The anti-static bar produces positive and negative ions which are blown onto the surface by the airknife. The electrons will now be exchanged, which causes the surface to be neutralised and the impurities to be removed. For use in hazardous zones, the Typhoon with the P-Sh-N-Ex anti-static bar is approved.

Typhoon with the Ep Sh N Ionising Bar

Airpressure sensor

Each Typhoon system is supplied with an airpressure sensor wich can measure the air pressure inside the airknife. If the pressure drops under the required level, the system does not work optimal. A system check is then neccessary, often it appears that the air filter needs to be cleaned.

Power unit A2A7M

Typhoon systems with EP-Sh-N anti-static bars incorporate a power unit type A2A7M. This unit contains an additional 12V power source for connection of the airpressure sensor.

Typhoon with the Ep-Sh-N Ionising Bar Highlights

  • Working distance up to 2000 mm
  • Surface cleaning
  • Low operational cost
  • Low noise

Full control of static electricity in your production process thanks to the IQ Easy Platform


Features

  • Incorporates Simco-Ion anti-static bars which quickly neutralize static, facilitating easy removal of particulate
  • Clean, uniform, high-velocity ionised air provides ‘‘one-step’’ cleaning
  • Direct-drive motors require little or no maintenance
  • Anodised finish for corrosion protection
  • Connection for pressure sensor
  • New design extruded aluminium profile
  • Cost efficient versus compressed air
  • Two mounting grooves
  • Small blower/ low noise level

Technical specification

Working distance 2000 mm max.
Working width on demand
Housing material aluminum
Ionizing bar material PVC
Emitter pin special alloy
Cable metal shielded
Weight 4 kg/m
Ambient temperature 0 – 55 °C
Use circumstances industrial
Operating voltage 7 kV AC
Air connection 75 mm Ø
Suitable power unit A2A7S/ A2A7M/ MPM
Approval UL

Product specification

Downloads